Ultraviolet Light Pilot Module UV100
Module consists of three UV systems: one UVC LED system at 280nm and two mercury systems at 253.7nm. The system types are on separate flow paths with individual flow control. Both flow paths are fed from a feed tank equipped with chemical injections and mixing that is perfect for pathogen spiking if so desired. The LED system is automatically controlled based on customer inputs of desired UV Dose and UV transmittance. The mercury systems will also adjust their power based on flowrate. Other features include superior on-board process diagnostics, automatic data logging of key parameters, secure remote monitoring and control over the internet, and email alarm notification.
Specifications
| Module | UV100 |
| UV Systems Information | AquiSense PearlAqua Kilo,
Viqua UVMax Pro20
Viqua UVMax Pro30,
|
| Flow Configurations | AquiSense and Viqua system can be run independently
Viqua System can be run in parallel or in series |
| Flow Range | 2 – 10GPM (7.57 – 37.85LPM) |
| Chemical Feed Systems | 2 |
| Chemical Feed Rate | 0.02…16.5 mL/min |
| Chemical Tank Volume | 3.75 gallon (14.2 L) |
| Power | 240 V AC, 1 phase, 60 Hz, 10 A |
| Options | Spare analog input module, shipping tarp |
| Operational Dimensions | 102″ (2.59 m) L x 48″ (1.22 m) W x 101″ (2.57 m) H |
| Shipping Dimensions | 102″ (2.59) L x 48″ (1.22 m) W x 90″ (2.29 m) H |
| Dry Weight | 2,200 lbs (998 kg) |
| Operating Weight | 3,500 lbs (1,588 kg) |
| Monitored Parameters | Feed Rate, Water Temperature Entering, Water Temperature Exiting, and Runtime for each UV system, UV Intensity for AquiSense system, Chemical Dosage, Chemical Flow, and Chemical Tank Level for each feed system, Feed Tank Level, Spare Analog Signals (3 qty.) |